CPR-1627-1M1LF



INPUT SPECIFICATIONS
Input voltage 90 - 140Vac / 180 - 264Vac
Input frequency 47 - 63 Hz
Input current 100 - 140V / 14.7 - 10.5A
180 - 240V / 11 - 8.3A
GENERAL SPECIFICATIONS
Hold-up time 18ms @ 75% Load
Efficiency at least 90%+ @ 50% Load
MTBF 100,000 hours at 25 degree C
ENVIRONMENTAL SPECIFICATIONS
Temperature 10 to 50 degree C Operating
Altitude 10,000 feet Operating
Relative humidity 20% to 90% RH Operating
OUTPUT SPECIFICATIONS
Voltage +12V +5Vsb
Regulation ±5% ±5%
Max Load 1200W : 100A
1620W : 132A
16A
Ripple & Noise 120mVp-p  50mVp-p 
Note:
  • The total output power can not exceed 1200W / 1620W for low / high line AC input respectively
  • During load changes from minimum to maximum or maximum to minimum the unit must not shut down
  • The outputs can exceed regulation limits (limited to UV/OV criteria) for steps greater than 85 amps